资源类型

期刊论文 905

年份

2024 1

2023 61

2022 79

2021 73

2020 48

2019 60

2018 64

2017 57

2016 31

2015 39

2014 58

2013 32

2012 18

2011 39

2010 44

2009 34

2008 39

2007 41

2006 13

2005 11

展开 ︾

关键词

过程强化 6

人工智能 5

优化 4

治疗 4

不确定性 3

DSM(设计结构矩阵) 2

SARS-CoV-2 2

三峡工程 2

催化剂 2

催化裂化 2

凝固过程 2

反渗透 2

层次分析法 2

废水 2

智能优化制造 2

智能制造 2

机器学习 2

流程工业 2

绿色制造 2

展开 ︾

检索范围:

排序: 展示方式:

Seasonal and treatment-process variations in invertebrates in drinking water treatment plants

Zhiling Wu, Xianchun Tang, Hongbin Chen

《环境科学与工程前沿(英文)》 2021年 第15卷 第4期 doi: 10.1007/s11783-020-1354-6

摘要: Abstract • Seasonal and treatment-process variations in invertebrates in a DWTP were analyzed. • The propagation and leakage of invertebrates in BAC filter were the most serious. • Invertebrates can survive and reproduce in chlorine disinfected clear water tanks. • Proportions of endogenous invertebrates increased along the treatment process. Problems associated with excessive propagation and leakage of invertebrates in drinking water have received increasing attention in recent years. We performed a monthly survey of invertebrate abundance and taxa in the effluent of each treatment stage in a drinking water treatment plant between May 2015 and April 2016 and analyzed seasonal and treatment-process variations in invertebrates. The results showed that invertebrate abundances in raw water, effluent of the biological activated carbon (BAC) filter, and finished water significantly correlated with water temperature, whereas no correlation was observed between water temperature and invertebrate abundance in the effluents of the sedimentation tank and sand filter. The dominant taxa in the effluent of each treatment stage were rotifers, nematodes, and crustaceans. The sedimentation tank could efficiently remove invertebrates with an annual average removal rate of 92%. The propagation and leakage of invertebrates occurred in the sand and BAC filters but more seriously in the latter. The average reproduction rate in the BAC filter was 268.8% with rotifers as the taxon that leaked the most. Invertebrate survival and reproduction were also observed in the chlorine-disinfected clean water reservoir with an average reproduction rate of 41.9%. Owing to differences in chlorine resistance, the reproduction ability of the dominant taxa was in the order nematodes>crustaceans>rotifers. The proportion of endogenous invertebrates gradually increased along the treatment process. The average proportion of endogenous invertebrates in the finished water was higher than 79.0%. Our findings suggested that waterworks should pay more attention to endogenous invertebrate growth.

关键词: Invertebrates     Drinking water     Seasonal variations     Treatment process    

Combined process of biofiltration and ozone oxidation as an advanced treatment process for wastewater

Xinwei LI,Hanchang SHI,Kuixiao LI,Liang ZHANG

《环境科学与工程前沿(英文)》 2015年 第9卷 第6期   页码 1076-1083 doi: 10.1007/s11783-015-0770-5

摘要: The effluent of a wastewater treatment plant was treated in a pilot plant for reclaimed water production through the denitrification biofilter (DNBF) process, ozonation (O ), and biologic aerated filtration (BAF). The combined process demonstrated good removal performance of conventional pollutants, including concentrations of chemical oxygen demand (27.8 mg·L ) and total nitrogen (9.9 mg·L ) in the final effluent, which met the local discharge standards and water reuse purposes. Micropollutants (e.g., antibiotics and endocrine-disrupting chemicals) were also significantly removed during the proposed process. Ozonation exhibited high antibiotic removal efficiencies, especially for tetracycline (94%). However, micropollutant removal efficiency was negatively affected by the nitrite produced by DNBF. Acute toxicity variations of the combined process were estimated by utilizing luminescent bacteria. Inhibition rate increased from 9% to 15% during ozonation. Carbonyl compound concentrations (e.g., aldehydes and ketones) also increased by 58% as by-products, which consequently increased toxicity. However, toxicity eventually became as low as that of the influent because the by-products were effectively removed by BAF. The combined DNBF/O /BAF process is suitable for the advanced treatment of reclaimed water because it can thoroughly remove pollutants and toxicity.

关键词: wastewater treatment     micropollutant removal     ozonation     biofiltration     toxicity    

Oxidative treatment of aqueous monochlorobenzene with thermally-activated persulfate

Qishi LUO

《环境科学与工程前沿(英文)》 2014年 第8卷 第2期   页码 188-194 doi: 10.1007/s11783-013-0544-x

摘要: The oxidation of aqueous monochlorobenzene (MCB) solutions using thermally- activated persulfate has been investigated. The influence of reaction temperature on the kinetics of MCB oxidation was examined, and the Arrenhius Equation rate constants at 20°C, 30°C, 40°C, 50°C, and 60°C for MCB oxidation performance were calculated as 0, 0.001, 0.002, 0.015, 0.057 min , which indicates that elevated temperature accelerated the rate. The most efficient molar ratio of persulfate/MCB for MCB oxidation was determined to be 200 to 1 and an increase in the rate constants suggests that the oxidation process proceeded more rapidly with increasing persulfate/MCB molar ratios. In addition, the reactivity of persulfate in contaminated water is partly influenced by the presence of background ions such as Cl , , , and . Importantly, a scavenging effect in rate constant was observed for both Cl and but not for other ions. The effective thermally activated persulfate oxidation of MCB in groundwater from a real contaminated site was achieved using both elevated reaction temperature and increased persulfate/MCB molar ratio.

关键词: persulfate     monochlorobenzene     advanced oxidation process    

Combination of the direct electro-Fenton process and bioremediation for the treatment of pyrene-contaminated

Wendi XU,Shuhai GUO,Gang LI,Fengmei LI,Bo WU,Xinhong GAN

《环境科学与工程前沿(英文)》 2015年 第9卷 第6期   页码 1096-1107 doi: 10.1007/s11783-015-0804-z

摘要: A combined treatment technology (DEF-BIO) using the direct electro-Fenton (DEF) process and bioremediation (BIO) was established in this study. The performance of the DEF-BIO process on the remediation of a pyrene (PYR)-contaminated soil was evaluated in a slurry reactor. The appropriate order of application was to conduct the DEF process followed by BIO, evaluated through analysis of the degradation characteristics of each process individually. In addition, the application time of the DEF process affected the efficiency of the combined process. The optimum time to apply the DEF process was determined through an analysis of the induced changes in PYR intermediates, pH, soil organic matter (SOM) and bacteria. The optimum application time of the DEF process was 6 h. All the induced changes were beneficial for the BIO phase. The removal of PYR was 91.02% for DEF–BIO after 72 h, and the efficiency was almost 50% increased, compared with the individual DEF and BIO treatments. Therefore, the combined process of DEF–BIO process may be an efficient and promising method for the remediation.

关键词: direct electro-Fenton     bioremediation     slurry reactor     combined process     pyrene    

Electrocoagulation process for the treatment of metal-plating wastewater: Kinetic modeling and energy

Fatih Ilhan, Kubra Ulucan-Altuntas, Yasar Avsar, Ugur Kurt, Arslan Saral

《环境科学与工程前沿(英文)》 2019年 第13卷 第5期 doi: 10.1007/s11783-019-1152-1

摘要: The wastewater from industrial area was treated by EC via Fe and Al electrodes. Cu, Ni, Cr and Zn were highly removed at the first minutes, simultaneously. Pseudo-2nd-order was found to be more suitable for kinetics. Adsorption capacities based on kinetic modeling were observed as Cr>Cu>Ni>Zn. The chemical cost in the case of pH adjustment after EC was less as 3.83 $/m3. It is known that wastewater produced by the metal-plating industry contains several heavy metals, which are acidic in nature and therefore toxic for the environment and for living creatures. In particular, heavy metals enter the food chain and accumulate in vital organs and cause serious illness. The precipitation of these metals is mostly achieved by pH adjustment, but as an alternative to this method, the electrocoagulation process has investigated in this study using iron and aluminum electrodes. The effects of the pH adjustment on removal before and after the electrocoagulation process were investigated, and cost analyses were also compared. It was observed that a high proportion of removal was obtained during the first minutes of the electrocoagulation process; thus, the current density did not have a great effect. In addition, the pH adjustment after the electrocoagulation process using iron electrodes, which are 10% more effective than aluminum electrodes, was found to be much more efficient than before the electrocoagulation process. In the process where kinetic modeling was applied, it was observed that the heavy metal removal mechanism was not solely due to the collapse of heavy metals at high pH values, and with this modeling, it was seen that this mechanism involved adsorption by iron and aluminum hydroxides formed during the electrocoagulation process. When comparing the ability of heavy metals to be adsorbed, the sequence was observed to be Cr>Cu>Ni>Zn, respectively.

关键词: Electrochemical treatment     Heavy metals     Kinetic modeling     Pseudo first order kinetic     Pseudo second order kinetic    

Applying chemical sedimentation process in drinking water treatment plant to address the emergent arsenic

Pengfei LIN,Xiaojian ZHANG,Hongwei YANG,Yong LI,Chao CHEN

《环境科学与工程前沿(英文)》 2015年 第9卷 第1期   页码 50-57 doi: 10.1007/s11783-014-0733-2

摘要: Arsenic (As) spills occurred more frequently and sometimes polluted water sources in recent years in China. It is as urgent need to develop emergency treatment technologies to address the arsenic threat for large-scale water treatment plants. In response, we developed a chemical sedimentation technology to remove arsenic contaminants for water treatment plants. Bench-scale experiments were conducted to investigate the efficiency of arsenic removal and the influencing factors of the chemical sedimentation treatment process. The influencing factors included the choice and dosage of coagulants, the valence of arsenic and pH value of solution. The As(V) contaminants can be almost completely removed by ferric or alum coagulants. The As(III) contaminants are more recalcitrant to chemical sedimentation, 75% for ferric coagulant and 40% for alum coagulant. The quantitative results of arsenic removal load by different ferric or alum coagulants were presented to help determine the parameters for arsenic treatment technology. The dominant mechanism for arsenic removal is static combination, or adsorption of negative arsenic species onto positive ferric hydroxide or alum hydroxide flocs. The efficiency of this treatment technology has also been demonstrated by a real production test in one water treatment plant with arsenic-rich source water and one emergency response. This technology was verified to be quick to set-up, easy to operate and highly efficient even for high concentration of arsenic.

关键词: Arsenic spill     chemical sedimentation     coagulation     drinking water     emergency treatment    

Comparative genotoxicity of water processed by three drinking water treatment plants with different watertreatment procedures

Ting Zhang, Heze Liu, Yiyuan Zhang, Wenjun Sun, Xiuwei Ao

《环境科学与工程前沿(英文)》 2020年 第14卷 第3期 doi: 10.1007/s11783-020-1214-4

摘要: Genotoxicity of substances is unknown in the water after treatment processes. Genotoxicity decreased by activated carbon treatment but increased by chlorination. Halogenated hydrocarbons and aromatic compounds contribute to genotoxicity. Genotoxicity was assessed by umu test; acute and chronic toxicity by ECOSAR. Inconsistent results confirmed that genotoxicity cannot be assessed by ECOSAR. Advanced water treatment is commonly used to remove micropollutants such as pesticides, endocrine disrupting chemicals, and disinfection byproducts in modern drinking water treatment plants. However, little attention has been paid to the changes in the genotoxicity of substances remaining in the water following the different water treatment processes. In this study, samples were collected from three drinking water treatment plants with different treatment processes. The treated water from each process was analyzed and compared for genotoxicity and the formation of organic compounds. The genotoxicity was evaluated by an umu test, and the acute and chronic toxicity was analyzed through Ecological Structure- Activity Relationship (ECOSAR). The results of the umu test indicated that biological activated carbon reduced the genotoxicity by 38%, 77%, and 46% in the three drinking water treatment plants, respectively, while chlorination increased the genotoxicity. Gas chromatograph-mass spectrometry analysis revealed that halogenated hydrocarbons and aromatic compounds were major contributors to genotoxicity. The results of ECOSAR were not consistent with those of the umu test. Therefore, we conclude that genotoxicity cannot be determined using ECOSAR .

关键词: Drinking water     Treatment process     Genotoxicity     Umu test     Ecological Structure-Activity Relationship    

Techno-economic characteristics of wastewater treatment plants retrofitted from the conventional activatedsludge process to the membrane bioreactor process

《环境科学与工程前沿(英文)》 doi: 10.1007/s11783-021-1483-6

摘要:

While a growing number of wastewater treatment plants (WWTPs) are being retrofitted from the conventional activated sludge (CAS) process to the membrane bioreactor (MBR) process, the debate on the techno-economy of MBR vs. CAS has continued and calls for a thorough assessment based on techno-economic valuation.

关键词: Membrane bioreactor (MBR)     Conventional activated sludge (CAS)     Cost-benefit analysis     Data envelopment analysis     Net profit    

Performance and mechanistic study on electrocoagulation process for municipal wastewater treatment based

Zhenlian Qi, Shijie You, Ranbin Liu, C. Joon Chuah

《环境科学与工程前沿(英文)》 2020年 第14卷 第3期 doi: 10.1007/s11783-020-1215-3

摘要: EC modified with BPEs enhances pollutant removal and reduce energy consumption. Increasing BPE number cannot increase flocculants yield exponentially. Simulations help to predict the distribution of electrochemical reactions on BPEs. The design of electrodes is crucial to electrocoagulation process (EC), specifically, with respect to pollutant removal and energy consumption. During EC, the mechanisms for interaction between different electrode arrangement and electrode reactions remain unclear. This work presents an integrated EC process based on horizontal bipolar electrodes (BPEs). In the electrochemical cell, the graphite plates are used as driving cathode while either Fe or Al plates serves as driving anode and BPEs. The BPEs are placed horizontally between the driving electrodes. For municipal wastewater treatment, the pollutant removal efficiency and energy consumption in different configurations of two-dimension electrocoagulation (2D-EC) system with horizontal BPEs were investigated. The removal efficiency of turbidity, total phosphorus and total organic carbon increased significantly with the number of BPEs. Noted that the energy consumption for TP removal decreased by 75.2% with Fe driving anode and 81.5% with Al driving anode than those of 2D-EC, respectively. In addition, the physical field simulation suggested the distributions of potential and current in electrolyte and that of induced charge density on BPE surface. This work provides a visual theoretical guidance to predict the distribution of reactions on BPEs for enhanced pollutant removal and energy saving based on electrocoagulation process for municipal wastewater treatment.

关键词: Electrocoagulation     Bipolar electrodes     Municipal wastewater     Simulations    

Distribution of PCDD/Fs in a food waste anaerobic digestion process with biogas utilization

《环境科学与工程前沿(英文)》 2023年 第17卷 第11期 doi: 10.1007/s11783-023-1736-7

摘要:

● The PCDD/F distribution patterns of the FW-AD process were investigated.

关键词: Biological treatment     MSW classification     Mass balance     Solid digestate    

A review on anammox process for the treatment of antibiotic-containing wastewater: Linking effects with

Jinjin Fu, Quan Zhang, Baocheng Huang, Niansi Fan, Rencun Jin

《环境科学与工程前沿(英文)》 2021年 第15卷 第1期 doi: 10.1007/s11783-020-1309-y

摘要: Abstract • Anammox is promising for nitrogen removal from antibiotic-containing wastewater. • Most antibiotics could inhibit the anammox performance and activity. • Antibiotic pressure promoted the increase in antibiotic resistance genes (ARGs). • Antibiotic-resistance mechanisms of anammox bacteria are speculated. Antibiotic is widely present in the effluent from livestock husbandry and the pharmaceutical industry. Antibiotics in wastewater usually have high biological toxicity and even promote the occurrence and transmission of antibiotic resistant bacteria and antibiotic resistance genes. Moreover, most antibiotic-containing wastewater contains high concentration of ammonia nitrogen. Improper treatment will lead to high risk to the surrounding environment and even human health. The anaerobic ammonium oxidation (anammox) with great economic benefit and good treatment effect is a promising process to remove nitrogen from antibiotic-containing wastewater. However, antibiotic inhibition has been observed in anammox applications. Therefore, a comprehensive overview of the single and combined effects of various antibiotics on the anammox system is conducted in this review with a focus on nitrogen removal performance, sludge properties, microbial community, antibiotic resistance genes and anammox-involved functional genes. Additionally, the influencing mechanism of antibiotics on anammox consortia is summarized. Remaining problems and future research needs are also proposed based on the presented summary. This review provides a better understanding of the influences of antibiotics on anammox and offers a direction to remove nitrogen from antibiotic-containing wastewater by the anammox process.

关键词: Anammox     Antibiotic     Mechanism     Inhibition    

Characteristics and removal mechanism of the precursors of N-chloro-2,2-dichloroacetamide in a drinking water treatmentprocess at Taihu Lake

《环境科学与工程前沿(英文)》 2021年 第15卷 第5期 doi: 10.1007/s11783-020-1338-6

摘要:

• N-Cl-DCAM, an emerging N-DBP in drinking water was investigated.

关键词: N-chloro-2     2-dichloroacetamide     Liquid chromatography with tandem mass spectrometry     Precursors     Removal efficiency     Ozonation integrated with biological activated carbon    

Removal of pharmaceutical and personal care products by sequential ultraviolet and ozonation processin a full-scale wastewater treatment plant

Qian SUI, Jun HUANG, Shuguang LU, Shubo DENG, Bin WANG, Wentao ZHAO, Zhaofu QIU, Gang YU

《环境科学与工程前沿(英文)》 2014年 第8卷 第1期   页码 62-68 doi: 10.1007/s11783-013-0518-z

摘要: The application of appropriate advanced treatment process in the municipal wastewater treatment plants (WWTPs) has become an important issue considering the elimination of emerging contaminants, such as pharmaceutical and personal care products (PPCPs). In the present study, the removal of 13 PPCPs belonging to different therapeutic classes by the sequential ultraviolet (UV) and ozonation process in a full-scale WWTP in Beijing was investigated over the course of ten months. Most of the target PPCPs were effectively removed, and the median removal efficiencies of individual PPCPs, ranging from -13% to 89%, were dependent on their reaction rate constants with molecular ozone. Noticeable fluctuation in the removal efficiencies of the same PPCPs was observed in different sampling campaigns. Nevertheless, the sequential UV and ozonation process still made a significant contribution to the total elimination of most PPCPs in the full-scale WWTP, by compensating for the poor or fluctuant removal performance of PPCPs by biologic treatment process.

关键词: PPCPs     advanced treatment     ozone     fluctuation     removal contribution    

From plasma to plasmonics: toward sustainable and clean water production through membranes

《化学科学与工程前沿(英文)》 2023年 第17卷 第12期   页码 1809-1836 doi: 10.1007/s11705-023-2339-3

摘要: The increasing demand for potable water is never-ending. Freshwater resources are scarce and stress is accumulating on other alternatives. Therefore, new technologies and novel optimization methods are developed for the existing processes. Membrane-based processes are among the most efficient methods for water treatment. Yet, membranes suffer from severe operational problems, namely fouling and temperature polarization. These effects can harm the membrane’s permeability, permeate recovery, and lifetime. To mitigate such effects, membranes can be treated through two techniques: plasma treatment (a surface modification technique), and treatment through the use of plasmonic materials (surface and bulk modification). This article showcases plasma- and plasmonic-based treatments in the context of water desalination/purification. It aims to offer a comprehensive review of the current developments in membrane-based water treatment technologies along with suggested directions to enhance its overall efficiency through careful selection of material and system design. Moreover, basic guidelines and strategies are outlined on the different membrane modification techniques to evaluate its prerequisites. Besides, we discuss the challenges and future developments about these membrane modification methods.

关键词: water treatment     membrane-based process     plasma treatment     plasma polymerization     plasmonic     light-to-heat conversion    

Partial anammox achieved in full scale biofilm process for typical domestic wastewater treatment

《环境科学与工程前沿(英文)》 2022年 第16卷 第3期 doi: 10.1007/s11783-021-1467-6

摘要:

• A full scale biofilm process was developed for typical domestic wastewater treatment.

关键词: Full scale     Anammox     Domestic wastewater     Biofilm     Candidatus Brocadia    

标题 作者 时间 类型 操作

Seasonal and treatment-process variations in invertebrates in drinking water treatment plants

Zhiling Wu, Xianchun Tang, Hongbin Chen

期刊论文

Combined process of biofiltration and ozone oxidation as an advanced treatment process for wastewater

Xinwei LI,Hanchang SHI,Kuixiao LI,Liang ZHANG

期刊论文

Oxidative treatment of aqueous monochlorobenzene with thermally-activated persulfate

Qishi LUO

期刊论文

Combination of the direct electro-Fenton process and bioremediation for the treatment of pyrene-contaminated

Wendi XU,Shuhai GUO,Gang LI,Fengmei LI,Bo WU,Xinhong GAN

期刊论文

Electrocoagulation process for the treatment of metal-plating wastewater: Kinetic modeling and energy

Fatih Ilhan, Kubra Ulucan-Altuntas, Yasar Avsar, Ugur Kurt, Arslan Saral

期刊论文

Applying chemical sedimentation process in drinking water treatment plant to address the emergent arsenic

Pengfei LIN,Xiaojian ZHANG,Hongwei YANG,Yong LI,Chao CHEN

期刊论文

Comparative genotoxicity of water processed by three drinking water treatment plants with different watertreatment procedures

Ting Zhang, Heze Liu, Yiyuan Zhang, Wenjun Sun, Xiuwei Ao

期刊论文

Techno-economic characteristics of wastewater treatment plants retrofitted from the conventional activatedsludge process to the membrane bioreactor process

期刊论文

Performance and mechanistic study on electrocoagulation process for municipal wastewater treatment based

Zhenlian Qi, Shijie You, Ranbin Liu, C. Joon Chuah

期刊论文

Distribution of PCDD/Fs in a food waste anaerobic digestion process with biogas utilization

期刊论文

A review on anammox process for the treatment of antibiotic-containing wastewater: Linking effects with

Jinjin Fu, Quan Zhang, Baocheng Huang, Niansi Fan, Rencun Jin

期刊论文

Characteristics and removal mechanism of the precursors of N-chloro-2,2-dichloroacetamide in a drinking water treatmentprocess at Taihu Lake

期刊论文

Removal of pharmaceutical and personal care products by sequential ultraviolet and ozonation processin a full-scale wastewater treatment plant

Qian SUI, Jun HUANG, Shuguang LU, Shubo DENG, Bin WANG, Wentao ZHAO, Zhaofu QIU, Gang YU

期刊论文

From plasma to plasmonics: toward sustainable and clean water production through membranes

期刊论文

Partial anammox achieved in full scale biofilm process for typical domestic wastewater treatment

期刊论文